We use cookies to ensure optimal usability of our website. By continuing to use the website, you agree to the use of cookies. Further information can also be found in our privacy policy. Accept cookies
Please enable cookies in your browser for this website.

Vector Group News

2017-07-28

CANalyzer 10.0 SP2

Download 32 Bit
Download 64 Bit

With Service Pack 2, the following changes become effective:

Diagnose Feature Set

  • Several small corrections

Option .Ethernet

  • Hardware filter for IPv4 and IPv6 addresses, UDP and TCP Ports are supported
  • The IP-Network driver for PC’s on board Ethernet ports now supports Windows 10
  • Improved handling of PDUs with same header ID and signal layout, transmitted in multiple VLANs.
  • Minor GUI improvements.
  • Fix an issue with VN5640 interface’s hardware filter in operation mode “Simulation” when all Ethernet packets shall be blocked
  • Fix an issue with VN5610(A) in Bypass mode which shows an erroneous Ethernet packet as forwarded error packet instead of error packet.
  • Fix an issue with VN5640 interface in operation mode „Direct Connection“ which may cause error messages if more than one channel is used.

CAPL

  • EthSetLinkStatus() now supports „on prestart“- and „on start“-handler in Simulated Bus mode, too.

Option .CANopen

  • For complex object a name space is created
  • Support for user specific data types
  • CAPL function to send EMCY messages
  • Improved CAN assignment with more than one assigned CAN channels

Option .AFDX

  • Extended settings for an AFDX channel (Light AFDX):
    • Abandonment of redundancy
    • Introduction of a minimal frame distance per end system (250 µs or 500 µs)
    • Maximum payload size 128 bytes or 256 bytes
  • Resolved Issues:
    • While replaying a logging file in offline mode, recorded BAG values are replayed.
    • Trace Window:
      • Highlighting of protocol errors in SNMP and TFTP has been corrected.
      • The detection of fragmentation errors at the end of a fragmented AFDX message has been corrected.
    • CAPL:
      • The output of manually configured AFDX messages (not configured in the database) by means of function A664TriggerMessage and mode 'Immediate' has been corrected
      • The initialization of selector SubVLid in FDS mode has been corrected.
      • The call of event procedures has been revised.

Option .A429

  • ARINC-429 Interactive Generator: Import and export of ARINC-429-Words incl. configuration
  • Resolved Issues:
    • Drag & drop of signals contained in multiplexed messages from the Trace Window to analysis filters or to the Data Window has been corrected
    • Replay ignores GAP errors now.
    • ARINC-429 Interactive Generator:
      • The input of physical values for BCD signals has been corrected.
      • The manual trigger mode is supported.
    • CAPL:
      • The use of function a429InitPayload for ARINC-429-Words which are not specified in the database has been corrected
      • The event procedure on a429Worderror was corrected and the detection of word errors improved.

Option .CANaero

  • Trace Window:
    • Specific icons for service events and for status events
    • The decoding of the PHSM (Periodic Health Status Message) has been corrected.