News

2009-08-12: CANape 7.0 SP5

Download

With Service Pack 5, the following changes become effective:

General Usage
  • Fixed problem with protected configuration having a floating graphic window.
  • Fixed measurement data issue when using "save signals" from graphic windows in specific cases.
  • Improved performance for 3D calibration window if a big array is modified.
  • Fixed issue in function ExportDatabase for devices without database.
  • Support synchronisation of value modification in 2D calibration window if the value is changed in another calibration window.
  • Support "go to working point" in 3D calibration window.
  • Fixed issue in display physical values of curves which refers a verbal conversion table.
  • Support synchronisation of calibration windows if a measurement object is displayed in this kind of window, too.
Communication Protocol
  • XCP: Fixed issue when displaying trace of WRITE_DAQ_MULTIPLE with more than 20 odt entries.
  • XCP on FlexRay: Fixed issue which lead to unchanged driver parameters.
  • XCP on FlexRay: Fixed several measurement issues.
Measurement (Enhanced measurement data acquisition)
  • Fixed sorting issue when inserting signals into measurement configuration.
  • Fixed measurement explorer instability after deleting signals imported by *.cfg file.
  • Fixed execution order of functions (according to measurement configuration) for modes OnStart, OnStop.
  • Support maps with dynamic axis point in feature "Create parameter set from measurement file".
Database
  • Fixed issue which occurred when using data window by offline processing/replacing MDF files containing structures.
  • Fixed computation error for structure size of ASCII string components.
  • Support of idents longer than 80 character in rules of dependend CHARACTERISTICS.
MATLAB/Simulink Support
  • Support of automatic generation of global variables for MATLAB/Simulink DLLs with buffered input blocks.
Data management (Optimized calibration data management(CDM Studio))
  • CDMStudio: Support drag&drop of complete trees in user defined filters.
  • Load PAR file which contains multiple device descriptions in the script method DEVICE.LoadParameterset.
  • Fixed issue in create report in CDM-Studio.
  • CDMStudio: Fixed issue reading DCM files which contains information of CHARACTERISTICS of type ASCII ¬†without A2L file. The value now will be read correctly.
Diagnostic (More extensive diagnostic options)
  • CANditoFlash: Fixed issue which lead to empty XML nodes when saving changes for tab "VFC | Files".
  • Override of byte padding handling (DLC) in Diagnostics driver settings dialog corrected.
  • All vehicle system group primitives are shown as active in Diagnostic Console Window even without detection patterns (or disabled detection).
  • Functional Tester Present messages are still sent periodically in presence of other functional requests
  • ODX improvements (improved support of unit qualifiers for COM-PARAMs, corrected handling if table-keys of different services reference the same conversion, handling of iterations inside a MUX improved, etc.).
  • Variant Identification works even if shortcut qualifiers are overridden in CDD.
Advanced Multimedia
  • Support of multiple triggered multimedia measurements with pretime in separate AVI files.
Was this page helpful?
E-Mail:

Please comment: