News

2012-07-11: DaVinci Developer 3.0.91 SP4

Download

With Service Pack 4 (Update to 3.0 Build 91), the following changes become effective:

Tool features:

  • Definition of End-to-End Protected connections available at the ECU project delegation ports to enable external generation of safety wrappers.
  • Port defined argument values (PDAV) can now be edited at the service component ports.
  • Enhanced compatibility with MICROSAR RTE generators allows usage of previous Rte version 2.17.2 (and newer) as external generator for this DaVinci Developer release. You can find a detailed overview with the compatible MICROSAR RTE versions at www.vector.com/rte_davinci/.

Usability enhancements:

  • Icons of the various DaVinci tools got a unique abbreviation to differentiate the tools more easily.
  • Check message export function has been enhanced with the detailed description and respects now the sorting order as specified in the list view.
  • Creation of mapped signal ports can now additionally create Software Component ports and connect them to the created ECU-Delegation port.

Fixed issues:

  • ARXML import of complex Data-Mapping was incomplete if an array data type to a signal group contains or is contained in another complex data type.
  • ARXML import of complex constants with CONSTANT-REFERENCEs was not correct.
  • Update of existing workspace with an ARXML import failed if a referenced Port-Interface or Mode-Declaration-Group was missing in the ARXML file.
  • If a service server port is mapped to a client port, it was not possible to map the port from the server side to another client port.
  • Consistency check of delegation connector ComSpec on ECU top-level was missing.
  • Consistency check #40259 created an inconsistency message even if the error trigger was correctly used with invalid handling.
  • Automatic creation of ports in data mapping failed in case of partially received signal group.
  • Consistency violation reported if scaled signal was mapped to an opaque data element.
  • Connectors in connector prototype list view were missing if a connector merge scenario was designed.
  • Relocation of a connection to a compatible delegation port was not visible due to missing graphic update.
  • DaVinci DEV freezes on certain handlings in the graphic if a large graphic model without sheets is designed.
  • Connection inconsistency error occurred due to wrong model update when changing the Component Type of a Component Prototype.
  • Service Mapping didn't show compatible ports correctly when using the 'show compatible Ports only' option in the selection dialog.
  • ARXML import aborts with E_FAIL error code when importing renamed record data-types referenced by record constants.
  • Wrong ComSignal handles in Rte because ARXML import didn't update the message to signal relation correctly in overwrite import mode.
  • Main window could not be restored if it was minimized running on Windows 7.
  • Wrong Init-Value consistency check message was reported if obsolete communication specifications existed.
  • Wrong display of some dialog controls on Chinese Windows has been corrected.
  • Auto-Connect created a connection between C/S and S/R which resulted in a consistency error.
  • Auto-Mapping has created wrong or inconsistent signal group mapping if naming rules and compatibility of elements was ambiguously.
  • If NvM memory blocks were configured and the according NvM service component was imported the consistency check may have been crashed.
  • Rte callbacks were missing if the same system signal was mapped on Rx and Tx port.
  • Bad performance while switching from structure design to port prototype view solved by specifiying the livst view as default editor for non-graphic use-cases.
  • ECU-C sychronize of Init Values produced unnecessary warning output.
  • Init value check for the Data Mapping didn't work.
  • Incorrect Exclusive Area Access after DCF loading if AR 2.1 SWC are used together with AR 3.0 ECU-C file.
  • Attribute definition inconsistencies weren't reported during DCF loading.
  • Inconsistent NvM block and PDAV order was not reported by a check.
  • Signal's unit was not imported via LDF file.
  • Crash has been fixed while opening ECU Project Software Design editor after large SWC was updated by importing new SWC definition.
  • Loading of global generic attribute definitions has been restructured to avoid overwriting with local attribute definition during DCF loading.
  • Wrong consistency message concerning maximum values was displayed due to rounding problems in physical value calculation.
  • Setup throwed an error message that product isn't installed when using the repair option.
  • Constraints and Limits properties of the data element prototype were ignored when importing.
  • In rare cases DCF load restored a wrong order index of the Task-Mapping.
  • Unintended message was shown if the ECU-Configuration file has been changed while closing DaVinci workspace.
  • Top-Level connections were not correctly removed during ECU-Extract update.
  • Obsolete ModeDisablingDependencies were not removed correctly during import.
  • Import of Multiple ECU Extract aborted with 'Item already in Set' error.
  • In some cases an error message was thrown during import update of LIN cluster with Sporadic Frames.
  • Import of Port Defined Argument Values with the same name was not possible.
  • Save Workspace As failed, if the workspace was read-only because it was created with a newer DaVinci version.
  • Workspace settings were reset on saving a DCF workspace as DEV.
  • Read-only ECU-Projects were missing after loading a DEV workspace which was created out of an DCF workspace.
  • Crash during DCF save has been fixed if many read-only DCF files are about to be stored.
  • Signal length was set to null after a LDF file has been updated through the ECU-Project signal list.
  • Data mapping was missing after loading DCF workspace if atomic software components were multiply instantiated within an ECU-Project.
  • Update icon was not correctly displayed in Attached-Files dialog.
  • ARXML import of incorrect MODE-DEPENDENCY aborted with "Unknown error" instead of printing an error message.
  • Special import feature couldn't be executed if a Project Assistant file was referenced in the ECU-Project.
  • An update of an ECU-Project failed with the message "Invalid argument" if a mapped Per-Instance-Memory wasn't overwritten due to the Import-Mode-Preset attribute.
  • Import of incorrect EXCLUSIVE-AREA-ACCESS aborted with "Unknown error" if the references to the exclusive area was invalid.
  • If the P-Port was a delegation port of a SW-Composition it was unable to connect an R-Port because of wrong incompatible direction error message.
  • If multiplexed ECUs exists the DaVinci DEV added ComSignal callbacks to the ECU-Configuration but the functions are not generated by the Rte generator.
  • Rte generation failed with an internal error if an ARXML with multiple mapping of the same system signal has been imported in prior.
  • After loading a DCF workspace the data mapping was lost for delegation ports which received a subset of a signal group.
  • ARXML import crashed if LIN event triggered frames were imported.
  • Import-Mode-Preset attribute didn't work for Mode Disabling Dependencies and port related triggers in the 'keep' use-case.
  • Save workspace in DCF format didn't work if BSWMD files with command line macros are specified in the ECU-Project.
  • OS Application dialog crashed on editing an existing OS Application if more than one OS Application is defined for a task.
  • A signal was treated as received through a frame although no rx relation existed. This results in an incorrect ECU-C synchronization because the signal was actually not used on Com layer.
  • Rte generation was wrong because Rx signal relation was missing for Tx/Rx signals sent between two instances of a Multiple-ECU project
  • Calibration port init values were not correctly updated on ARXML import of existing software components.
  • Graphic update was missing if 'complete delegation port' has been executed in a separate view.
  • Data mapping was not imported/updated correctly in ARXML import of a Multiple-Ecu configuration with complex data types.
  • Superflous COM_SendSignal calls existed in Rte code if the same System-Signal was mapped to several Tx/Rx-Frames.
  • Data mapping was lost on loading DCF workspace if not all data elements of a delegation port were connected to an atomic port prototype.
  • USB dongle access caused GUI freeze in some situations.
  • Wrong consistency check message fixed that the Rx-Signal bit length didn't fit into the data element.

 

 